IFCDP1001 [WFCD1 + MIP1000] Varilight V-Plus Series 1 Gang 200-1000 Watt/VA Dimmer Ultra Flat Polished Chrome Coated On a Double Plate
#IFCDP1001 [WFCD1 + MIP1000]
GTIN: 5021575842418
£29.75
£24.79
IFCDP1001 Varilight V-Plus Single 1 or 2 way 1000 watt/VA push-on/off Rotary Dimmer on a Double Plate, Ultra Flat Polished Chrome Coated 1mm-Thin Plate and Polished Chrome Knob.
This is a self-assembly kit made up of the Matrix Components: [WFCD1 + MIP1000]
✔ Intelligent dimming technology
✔ Leading Edge for dimming Mains Halogen and Incandescent bulbs
✔ Also dims Electronic Low Voltage circuits
✔ Soft-Start feature to extend lamp life and halt electrical spikes
✔ Self re-setting Overload Protection
✔ Contains Heat Sensor to stop dimmer damage
✔ Suitable for either 1 way or 2 way circuits
✔ Max Load 1000 Watt
✔ Min Load 200 Watt
✔ Contemporary, ultra-slim faceplate
✔ Fits in a 35mm Deep Wall Box
This is a self-assembly kit made up of the Matrix Components: [WFCD1 + MIP1000]
✔ Intelligent dimming technology
✔ Leading Edge for dimming Mains Halogen and Incandescent bulbs
✔ Also dims Electronic Low Voltage circuits
✔ Soft-Start feature to extend lamp life and halt electrical spikes
✔ Self re-setting Overload Protection
✔ Contains Heat Sensor to stop dimmer damage
✔ Suitable for either 1 way or 2 way circuits
✔ Max Load 1000 Watt
✔ Min Load 200 Watt
✔ Contemporary, ultra-slim faceplate
✔ Fits in a 35mm Deep Wall Box
Availability:
In stock
SKU
IFCDP1001 [WFCD1 + MIP1000]
Varilight V-Plus Series 1 Gang, for either 1 or 2 Way circuits, 200-1000 Watt/VA, Push-on/Push-off Dimmer Switch, on a Double Plate, is ideal for dimming mains and almost all Low Voltage applications, and is especially suited for upto 1000 Watts of Halogen or GLS Lighting.
..................................................
VARILIGHT Dimmer Switches have an industry-wide reputation for exceptional performance, long life and innovation at attractive prices.
..................................................
The VARILIGHT V-Plus Series Dimmer, like all our products, is designed to meet the latest European Safety Legislation.
..................................................
It is important to select the correct dimmer switch for your application, so please read the following information carefully, if need be look at PDF manuals, and if you are still unsure, then contact us.
..................................................
Appearance, Function and Applications
This dimmer is push on/off and rotary controlled, meaning to turn the dimmer on or off simply push the dimmer knob in and it will click back out; then to turn the brightness up or down, rotate the knob clockwise and anti-clockwise.
..................................................
V-Plus Push on/off dimmers are also suitable for either 1 way, or 2 way circuits. What does 1 or 2 way mean? It means you are able to use this type of dimmer for both 1 way circuits (1 dimmer controlling 1 light) and 2 way circuits (1 dimmer and 1 switch controlling the same light). If the lighting circuit is controlled by 1 dimmer and 2 switches (3 way), in seperate locations then one of the switches in the circuit must be an Intermediate Switch with four terminals enabling you to link all three switches together.
..................................................
V-Plus Series Dimmers are Leading Edge and can be used with mains voltage lighting and good quality Low Voltage Electronic Transformers.
..................................................
The V-Plus Series Push on/off Dimmers can be used for mains incandescent GLS lamps (standard mains light bulbs), up to the maximum load as specified on the dimmer.
..................................................
The V-Plus Series can also dim GU10 or similar Hi Spot Mains Halogen lamps (only use quality UK supplied lamps) up to the maximum load as shown in the PDF instruction manual.
..................................................
When using Electronic Low Voltage Transformers we recommend that a maximum of 5 good quality dimmable Electronic Transformers are used (10 if Varilight Transformers) with this dimmer range. Please note: add the watts of the bulbs/lamps if using Varilight Transformers, to determine which wattage of dimmer to select, but if using another manufacturer of Transformer, add up the VA of the Transformers so it does not exceed the maximum of the dimmer. Please note that noise levels can depend on the quality of the Transformer being used.
..................................................
The V-Plus Series Push on/off Dimmers can be used in 2 way circuits (where one lighting circuit is controlled from two locations). In order to achieve 2 way switching, they must be paired with a standard 2 way switch in the other location.
3-way switching can be achieved by adding an intermediate switch in to the circuit. When using V-Plus Series Push on/off Dimmers in a 2 or 3 way circuit the lights can only be dimmed from the location that the dimmer is situated in, if total dimming is preferred from many switched locations, in a 2, 3 or more way circuit then choose the Varilight Touch and Remote range of dimmers, in conjunction with Slave Dimmers.
..................................................
The V-Plus Series are equipped with some intelligent features: Soft-Start Technology, allows a longer life span of the bulbs or lamps used by increasing the brightness level softly, which also creates a welcoming effect; Self Re-setting Overload Protection, so is able to handle overload situations, for example, if the wattage of the bulbs/lamps are accidentally too high on a circuit. This is achieved by either, stepping down the dimmer's output to the lamps (if the watts are marginally overloaded), or the dimmer cuts out before there is any damage, (if the watts are grossly overloaded), until the load is reduced; Intelligent Heat Sensor which again stops damage to the dimmer, if it becomes too hot.
..................................................
Limitations
These dimmers will NOT dim LEDs, if dimming LEDs choose either the V-Pro, Multi-Point Remote, Multi-Point Touch, or V-Com Dimmer Series.
Do not use this dimmerswitch for fluorescent bulbs, energy saving bulbs or fans. The dimmerswitch will eventually be damaged beyond repair if used for these applications. Incorrect use will make your guarantee invalid.
..................................................
Varilight Dimmers can NOT be used for wire-wound or torroidal Transformers. For Fan applications choose V-Dim Solid State Series, please check with manufacturer of appliance to be dimmed.
..................................................
Cleaning
This product can be easily cleaned with a soft dry micro-fibre cloth. Never apply masking tape or other similar tape to the product. Avoid the use of any cleaning chemicals and always use a Gasket on freshly plastered, painted or damp walls as the plates may tarnish. (Plaster can take up to 6 months to dry out). A Gasket can be made from the packaging the product comes in, or a plastic bag can be cut to stop the plate touching the plaster. Unfortunately, if these Instructions are not followed, and the plate is damaged, it will void the product warranty.
..................................................
Product Instructions & Manuals
- Intelligent Dimmer Instructions PDF
- V-Plus Dimmer Series Compatibility Guide PDF
- Compatibility Detailed PDF
- Compatibility Overview PDF
..................................................
VARILIGHT Dimmer Switches have an industry-wide reputation for exceptional performance, long life and innovation at attractive prices.
..................................................
The VARILIGHT V-Plus Series Dimmer, like all our products, is designed to meet the latest European Safety Legislation.
..................................................
It is important to select the correct dimmer switch for your application, so please read the following information carefully, if need be look at PDF manuals, and if you are still unsure, then contact us.
..................................................
Appearance, Function and Applications
This dimmer is push on/off and rotary controlled, meaning to turn the dimmer on or off simply push the dimmer knob in and it will click back out; then to turn the brightness up or down, rotate the knob clockwise and anti-clockwise.
..................................................
V-Plus Push on/off dimmers are also suitable for either 1 way, or 2 way circuits. What does 1 or 2 way mean? It means you are able to use this type of dimmer for both 1 way circuits (1 dimmer controlling 1 light) and 2 way circuits (1 dimmer and 1 switch controlling the same light). If the lighting circuit is controlled by 1 dimmer and 2 switches (3 way), in seperate locations then one of the switches in the circuit must be an Intermediate Switch with four terminals enabling you to link all three switches together.
..................................................
V-Plus Series Dimmers are Leading Edge and can be used with mains voltage lighting and good quality Low Voltage Electronic Transformers.
..................................................
The V-Plus Series Push on/off Dimmers can be used for mains incandescent GLS lamps (standard mains light bulbs), up to the maximum load as specified on the dimmer.
..................................................
The V-Plus Series can also dim GU10 or similar Hi Spot Mains Halogen lamps (only use quality UK supplied lamps) up to the maximum load as shown in the PDF instruction manual.
..................................................
When using Electronic Low Voltage Transformers we recommend that a maximum of 5 good quality dimmable Electronic Transformers are used (10 if Varilight Transformers) with this dimmer range. Please note: add the watts of the bulbs/lamps if using Varilight Transformers, to determine which wattage of dimmer to select, but if using another manufacturer of Transformer, add up the VA of the Transformers so it does not exceed the maximum of the dimmer. Please note that noise levels can depend on the quality of the Transformer being used.
..................................................
The V-Plus Series Push on/off Dimmers can be used in 2 way circuits (where one lighting circuit is controlled from two locations). In order to achieve 2 way switching, they must be paired with a standard 2 way switch in the other location.
3-way switching can be achieved by adding an intermediate switch in to the circuit. When using V-Plus Series Push on/off Dimmers in a 2 or 3 way circuit the lights can only be dimmed from the location that the dimmer is situated in, if total dimming is preferred from many switched locations, in a 2, 3 or more way circuit then choose the Varilight Touch and Remote range of dimmers, in conjunction with Slave Dimmers.
..................................................
The V-Plus Series are equipped with some intelligent features: Soft-Start Technology, allows a longer life span of the bulbs or lamps used by increasing the brightness level softly, which also creates a welcoming effect; Self Re-setting Overload Protection, so is able to handle overload situations, for example, if the wattage of the bulbs/lamps are accidentally too high on a circuit. This is achieved by either, stepping down the dimmer's output to the lamps (if the watts are marginally overloaded), or the dimmer cuts out before there is any damage, (if the watts are grossly overloaded), until the load is reduced; Intelligent Heat Sensor which again stops damage to the dimmer, if it becomes too hot.
..................................................
Limitations
These dimmers will NOT dim LEDs, if dimming LEDs choose either the V-Pro, Multi-Point Remote, Multi-Point Touch, or V-Com Dimmer Series.
Do not use this dimmerswitch for fluorescent bulbs, energy saving bulbs or fans. The dimmerswitch will eventually be damaged beyond repair if used for these applications. Incorrect use will make your guarantee invalid.
..................................................
Varilight Dimmers can NOT be used for wire-wound or torroidal Transformers. For Fan applications choose V-Dim Solid State Series, please check with manufacturer of appliance to be dimmed.
..................................................
Cleaning
This product can be easily cleaned with a soft dry micro-fibre cloth. Never apply masking tape or other similar tape to the product. Avoid the use of any cleaning chemicals and always use a Gasket on freshly plastered, painted or damp walls as the plates may tarnish. (Plaster can take up to 6 months to dry out). A Gasket can be made from the packaging the product comes in, or a plastic bag can be cut to stop the plate touching the plaster. Unfortunately, if these Instructions are not followed, and the plate is damaged, it will void the product warranty.
..................................................
Product Instructions & Manuals
- Intelligent Dimmer Instructions PDF
- V-Plus Dimmer Series Compatibility Guide PDF
- Compatibility Detailed PDF
- Compatibility Overview PDF
Plate Finish | Polished Chrome |
---|---|
Dimmer Features | Soft Start Feature, Overload Protection |
Dimmer Gangs | 1 Gang Dimmer |
Dimmer Circuits | 2 Way |
Write Your Own Review
Product Features
✔ Intelligent dimming technology
✔ Leading Edge for dimming Mains Halogen and Incandescent bulbs
✔ Also dims Electronic Low Voltage circuits
✔ Soft-Start feature to extend lamp life and halt electrical spikes
✔ Self re-setting Overload Protection
✔ Contains Heat Sensor to stop dimmer damage
✔ Suitable for either 1 way or 2 way circuits
✔ Max Load 1000 Watt
✔ Min Load 200 Watt
✔ Contemporary, ultra-slim faceplate
✔ Fits in a 35mm Deep Wall Box
..................................................
Range: Ultra Flat
Finish: Polished Chrome Coated
Product Category: V-Plus Dimmer
Insert/Knob Colour: Polished Chrome Knob
Dimensions: 89x149x48mm
Faceplate Depth: 1mm
Product Weight: 240g
Fixing Centres: 120.6mm
Recommended Back Box Depth: 35mm
Operating Voltage: 220/250V AC
Maximum Load Rating: Halogen: 1000W
Maximum Current Rating: 4.3A
Terminal (Live) Diameter: 3.2mm; Capacity: 3 x 1.5mm²
Terminal (Earth) Diameter: 3.3mm; Capacity: 3 x 1.5mm²
..................................................
Intended Applications: Indoor Use Only. Domestic lighting circuits.
Safety Advice: Do not overload. Product Must Be Earthed.
Applicable Safety Standard: BS EN 60669-2-1